49. OUTER TUB FRONT PANEL
a. Remove screws holding control panel to
control cabinet.
b. Remove control panel away from control
cabinet. Refer to Figure 7.
c. Working through control panel opening,
remove two screws holding bottom flange of
control cabinet sides to top flange of front
panel. Refer to Figure 15.
d. While supporting lower front access panel,
remove two screws from bottom edge of panel.
Refer to Figure 8.
e. Gently lower access panel to disengage panel
locators from bottom edge of front panel. Refer
to Figure 8.
f. Remove dispenser drawer using the special
tool, No. 318P4. Refer to Figure 13.
g. Open loading door and carefully remove wire
clamp ring from groove with small flat blade
screwdriver. Spring is located at 6 o’clock
position. Refer to Figure 16.
NOTE: To avoid damage to spring, use screwdriver
on wire clamp ring to right or left of spring.
h. Grasp loading door seal lip. Refer to Figure 14,
Step 1.
NOTE: To avoid damage to door seal, DO NOT use
pliers or sharp objects to grasp the door seal lip. If
lip is damaged, seal will leak.
i. Using a circular motion, pull seal up
(Figure 14, Step 1), out (Figure 14, Step 2), and
down (Figure 14, Step 3).
j. When seal releases from lip of front panel, pull
out and remove the seal from front panel around
door opening. Refer to Figure 14, Step 4.
NOTE: Door seal installation can be improved
using water or soap solution to work seal around
circumference of loading door opening. Be sure to
orientate seal with the tab in the 12 o’clock position.
When installing wire clamp ring to front panel, be
careful not to overstretch tension spring.
k. While supporting the front panel assembly,
remove the two bottom front corner screws.
Refer to Figure 15.
l. Remove front panel (with loading door
attached) away from washer as far as wires
permit.
m. Unplug wire harness from both the door latch
switch and from the door switch. Refer to
Figure 15. Remove clips holding wire harness
and door seal hose along top flange of front
panel and remove front panel.
NOTE: The large wire clip holds both the wire
harnesses and the door seal hose.
n. Loosen hose clamp and remove dispenser
valve-to-door seal hose connection at the
dispenser. Refer to Figure 18.
IMPORTANT: When installing door seal hose, pull
hose tie tight to prevent damage. Refer to Figure 18.
o. Loosen large clamp holding door seal to front
of outer tub. Carefully pull seal off front lip of
outer tub front panel and remove door seal and
hose. Refer to Figure 18.
p. Disconnect ground wire from outer tub front
panel. Refer to Figure 20.
q. Remove nut, washers and screw holding clamp
ring to outer tub front panel. Refer to Figure 20.
r. Remove rubber seal from outer tub front panel
and discard seal.