112
801805
Section 6 Adjustments
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect all electric power to the machine and accessories before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start machine with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
• Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
85. BURNER FLAME (Gas Models)
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
to Figure 27.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. Refer
to Figure 35.
c. Set timer to 60 minutes.
d. Close the loading door. Start the dryer in a heat
setting (refer to Operating Instructions supplied
with the dryer). The dryer will start, the igniter
will glow red, and the main burner will ignite.
e. Allow the dryer to operate for approximately
five minutes, then loosen the air shutter
lockscrew. Refer to Figure 63.
f. Turn the air shutter to the left to get a luminous
yellow tipped flame, then turn it back slowly to
the right to obtain a steady blue flame.
g. After proper flame is obtained, tighten air
shutter lockscrew firmly. Refer to Figure 63.
h. Reinstall access panel and screws.
NOTE: After the dryer has operated for
approximately three minutes, exhaust air or
exhaust pipe should be warm.
To reduce the risk of fire or serious injury,
the access panel must be in place during
normal operation.
W262
WARNING
Figure 63
Air Shutter
Lockscrew
Air
Shutter
Shut-Off
Valve
Handle
1/8 Inch Pipe Plug
(For checking manifold pressure)
D265SE3A