96
801805
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect all electric power to the machine and accessories before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start machine with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
• Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
i. Front Cylinder Seal (Refer to Figure 50.)
When installing the cylinder seal, it is important
to remember these two steps:
(1) The stitching on the seal must face towards
center of dryer.
(2) The short flap must be glued to the
bulkhead and the long flap left loose.
IMPORTANT: The replacement seal can be
adhered to the bulkhead using No. 22506P Sealant.
This is accomplished by applying a bead of sealant
around the entire flanged area where the felt seal
contacts the bulkhead.
Figure 50
Bulkhead
Long Flap
Seal Stitching
(Must face towards
center of dryer)
Short Flap
(Must be glued
to bulkhead)
D257SE3A