Publication 2711P-UM001B-EN-P
5-20
Installing and Replacing Components
PanelView Plus 700-1500 Terminals
The F1-Fxx and K1-Kxx legend inserts on the PanelView Plus 700 -
1500 terminals are accessible when the Display Module bezel is
removed.
To replace the F1-Fxx or K1-Kxx function key legends:
1.
Remove power from the terminal.
2.
Remove the Display Module bezel as described on page 5-13.
3.
Pull the legend inserts out from the slots on the bezel.
4.
Insert the new legend strips into the same slots until only the
end tab is visible.
5.
Replace the Display Module bezel as described page 5-14.
Using an External Compact
Flash Card
All of the PanelView Plus terminals have a Compact Flash Card slot.
The 400-600 terminals support Type I Compact Flash cards; the
700-1500 terminals support Type I/II Compact Flash cards. These
cards (2711P-RCx) are available in different memory sizes.
Compact Flash Card Slot