40
Rockwell Automation Publication 825-UM004D-EN-P - November 2012
Chapter 3
Front Panel Operation
Front Panel Main Menu
All access to information and relay settings through the front panel starts at the
relay main menu. The remainder of this section describes the use of the main and
lower level menus.
Yes/No
Reset Stats
Trip Alarm
Overload
Undercur
Jam
Curr Imb
Shrt Ckt
GF
Speed SW
Undrfreq
Overfreq
Lckd Rot
Ph Rever
St Timer
Rem Trip
Other
Total
Rset Date
Rset Time
Run Time
Stop Time
Time run
# of starts
E starts
Motor Monitor
Targets
Relay
Main Settings
Overload Set
Short Ckt Set
GF-CB Settings
GF-Res Settings
Jam Settings
Under Current Set
Current Imb Set
Trip Level Trip Delay Warn Lvl Warn Dly
Trip Lvl Trip Dly Warn Lvl Warn Dly
Trip Lvl Trip Dly Warn Lvl Warn Dly
Trip Lvl Trip Dly Warn Lvl Warn Dly
Trip Lvl Trip Dly Warn Lvl Warn Dly
Trip Level Trip Delay Warn Lvl Warn Dly Start Inh
Prot. Disable
Prot Inh OL Inh
Start Monitor
St Mtr Time
Star-Delta Set
Star-Del En Max Star T
Start Inhibit Set
Start/Hr Min Off T Rstrt blk T
Phase Rev Set
Ph Rv En
Speed SW Set
Trip Dly Warn Dly
PTC Settings
PTC En PTC Rst
RTD Settings
RTD En RTD Rst RTD* Loc RTD* Type RTD* Trip RTD* Warn Wdng Trip Bear Trip TMP Bias
Freq Settings
F1 Trip Lvl F1 Trip Dly F1 Wrn Lvl F1 Wrn Dly F2 Trip Lvl F2 Trip Dly F2 Wrn Lvl F2 Wrn Dly
Load Control Set
Load Ctrl Ctrl Up Ctrl Low
I/O Settings
Analog O
Trip Inhibit
Curr Imb
PTC RTD
Short Ckt Undercurr Start Inh
Jam GF
Relay Behavior
Trip Fl-Sfe Aux1 Fl-Sfe Aux2 Fl-Sfe Aux3 Fl-Sfe Aux4 Fl-Sfe Aux5 Fl-Sfe Aux6 Fl-Sfe
Timer Settings
On Dly T1 Off Dly T1 On Dly T2 Off Dly T2
Front Panel Set
LCD Time LCD Cntrst
Display Enable
Time/Date Gr Curr Curr Imb Freq TCU RTD Temp Volt Imb Power
OL Enable
Reset MD
Reset Lvl
Serv Fact
Mtr LRC
LRT
Accl Fact
Rn ST TC
Mtr LRC-2
Mtr LRT-2
Accl Fact-2
ST TC-2nd
OL Warn Lvl
St Inh Lvl
Stop Cool T
OL Biasing
Ph Rot
Rated Freq
Date
Ph CT
Mtr FLA
2-speed
CT-2nd
Mtr FLA-2
FVR Ph
Cr B CT
Ph VT
Line Volt
XFMR
IO Assign
Port
DTE Time
Passwrd
Status
Reset
TCU
Reset
Energies
Restore/
Reboot
Reset
Access Level
Set/
Show
Meter
Instant
Thermal
Mtr Load
TCU
Thrm Trip
T to Rset
Port F Port 4
Trip Rly
Aux 1
Date
New PW
Time
Aux 2
In 1
In 2
Speed
Data Bits
Parity
Stop Bits
Port TO
Hndshke
Com Int
Protocol
Speed
Parity
Slave ID
L1 Curr
L1 Angle
L2 Curr
L2 Angle
L3 Curr
L3 Angle
GF Cur (8)
GF-CB An
GR (Res)
GF Ang
Avg Curr
Mtr Load
Curr Imb
Freq
Yes/No
Dsp
Event
Reset
Event
Events
Main
Mtr Use
Summary of Contents for 825-P
Page 1: ...Modular Protection System for Motors Catalog Number 825 P User Manual...
Page 4: ...4 Rockwell Automation Publication 825 UM004D EN P November...
Page 64: ...64 Rockwell Automation Publication825 UM004D EN P November 2012 Chapter 5 Using MPS Explorer...
Page 234: ...234 Rockwell Automation Publication 825 UM004D EN P April 2012 Chapter B ParameterList...
Page 265: ......