Translation of original operating instructions
32
AL-KO AT4F ATEX
4.2.3.4 Crane transport using crane eyelets
Transporting the unit using crane eyelets is permissible up to a width of 49 grids!
Suspension on crane eyelets
Max. permissible weight of the individual components
Suspension via 4 crane eyelets
1500 kg
Suspension via 4 crane eyelets and additional 2 centre eyelets
2500 kg
Transport with crane eyelets:
The attached crane and centre eyelets must be used for the transport of all components.
All crane and centre eyelets on the AT4F ATEX unit must be used and
evenly
loaded! A crane harness (spreader
beam and chain hoist) is to be used for 6 suspension options and above!
An
angle of more than 45° and less than 80°
must be maintained between rope and unit roof.
On the crane and centre eyelets, a shackle (not supplied) must be attached on-site. To do this, a hole diameter of
22 mm is provided for.
The crane and centre eyelets must be removed before beginning the unit connection assembly work.
After removing the crane eyelets, the openings are to be sealed airtight with sealing plugs d = 12 mm (included as
accessories).
Horizontal pulling on the crane eyelets is not permitted.
1
2
3
4
5
Fig. 14 Crane eyelets
1
Hexagon head bolt M12x80 (min. Strength class 10.9)
4
Sealing plug (insert after removing the crane eyelets)
2
Crane eyelet
5
Centre eyelet (present depending on the roof construction)
3
Bushing
4.3
Storage prior to assembly
Store the individual functional parts in a dry and weatherproof location in their original packaging.
Store the functional parts in the temperature range of -20 °C to +40 °C.
Cover open pallets with tarpaulins, and protect the functional parts from dirt (e.g. chips, stones, wire, etc.).
Frequent and, above all, abrupt temperature changes must be avoided during storage. This is especially harmful if
moisture is able to form condensation.
To avoid bearing damage, the fan must be rotated monthly if at a standstill for more than one month.
For storage periods of more than 1 year, check the ease of movement of the fans' bearings (by turning by hand)
before assembly.
Avoid distorting the housing or other damage during storage.
Damage resulting from improper packaging and storage are at the expense of the initiator.