background image

Introduction

CETO100 (fig. 1) is a centrifgual fan designed to ensure
air extraction in small/medium-sized rooms such as bathrooms, toilets and kitchens. 
Suitable for air discharge through long length ducting.
Wall or ceiling installation, surface or recessed in plasterboard walls (fig.2).

Read this manual carefully before using the product and keep it in a safe place for reference. 
This product was constructed up to standard and in compliance with regulations relating to electrical equipment and must be installed by techni-
cally qualified personnel.
The manufacturer assumes no responsibility for damage to persons or property resulting from failure to observe the regulations contained in this 
booklet.

• Material: High quality, impact and UV-resistant ABS colour RAL 9010
• Design front cover removable for cleaning without the use of tools
• Highly quality forward-curved impeller for high performance and top silence.
• Single phase 2-speed motor with integral thermal protection.
• Motor mounted on ball bearings that guarantee a longer product life cycle (30,000 h) and suitable for cold climates
• The fan is double insulated: no earth connection is required
• Suitable for continuous or intermittent operation
• IPX4 degree of protection
• Power supply 220V to 240V

50/60Hz

• The device should not be used for applications other than those specified in this manual.
• After removing the product from its packaging, verify its condition. In case of doubt, contact a qualified technician. Do not leave packaging 

within the reach of small children or people with disabilities. 

• Do not touch the appliance with wet or damp hands/feet.
• The device is not intended for use by persons (including children) with reduced physical, sensory or mental capacities or those with a lack of 

experience and knowledge, unless they have been given supervision or instruction concerning use of the device from a person responsible for 
their safety. 

   Children should be supervised to ensure that they do not play with the device.
• Do not use the product in the presence of inflammable vapours, such as alcohol, insecticides, gasoline, etc.
• If any abnormalities in operation are detected, disconnect the device from the mains supply and contact a qualified technician immediately. Use 

original spare parts only for repairs.

• The electrical system to which the device is connected must comply with regulations.
• Before connecting the product to the power supply or the power outlet, ensure that:
   - the data plate (voltage and frequency) correspond to those of the electrical mains
   - the electrical power supply/socket is adequate for maximum device power. If not, contact a qualified technician.
• The device should not be used as an activator for water heaters, stoves, etc., nor should it discharge into hot air/fume vent ducts deriving from 

any type of combustion unit. It must expel air outside via its own special duct.

• Operating temperature: 0°C up to +50 °C.
• The device is designed to extract clean air only, i.e. without grease, soot, chemical or corrosive agents, or flammable or explosive mixtures. 
• Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.). 
• Do not immerse the device or its parts in water or other liquids.
• Turn off the main switch whenever a malfunction is detected or when cleaning.
• For installation an omnipolar switch should be incorporated in the fixed wiring, in accordance with the wiring regulations, to provide a full 

disconnection under overvoltage category III conditions (contact opening distance equal to or greater than 3mm).

Installation manual

CETO100 - Centrifugal fan

Fig. 1

TECHNICAL SPECIFICATIONS

PRECAUTIONS FOR INSTALLATION, USE AND MAINTENANCE

G

Model

Airflow

(max)

Static pressure

Pa max

Power

W max

Sound pressure

dB(A) @3m

L/s

m

3

/h

CETO100

28.8/17.3 104/62

251/142

28/17

38/27

Summary of Contents for CETO100

Page 1: ... unless they have been given supervision or instruction concerning use of the device from a person responsible for their safety Children should be supervised to ensure that they do not play with the device Do not use the product in the presence of inflammable vapours such as alcohol insecticides gasoline etc If any abnormalities in operation are detected disconnect the device from the mains supply...

Page 2: ...ected according to the diagram in figure 45C after the light is switched on the fan activates with a delay of max 1 5 seconds After the light is switched off the fan continues to function for a pre set period of time WITH HUMIDISTAT TIMER The fan is equipped with a humidity detector whose threshold is adjustable from 50 to 95 Relative Humidity and with a timer which is adjustable from aprox 1 minu...

Page 3: ...3 INSTALLATION Fig 2 ceiling recessed wall recessed perimetrical exhausting wall surface ceiling surface accessory on demand ...

Page 4: ...4 5 6 7 8 MOUNTING 3 4 CETO100 Ø 96mm Ø ...

Page 5: ...5 10A 11A 9A 3 x Ø 5mm SURFACE INSTALLATION 2 X 0 5 1 5 mm2 3 X 0 5 1 5 mm2 3 X 0 5 1 5 mm2 4 X 0 5 1 mm2 BASE STD T HT SURFACE CABLE H03VV F H05VV F 12A 13A 14A 150mm 5mm ...

Page 6: ...6 12B 13B 14B 150mm 11B 10B 9B 3 x Ø 5mm RECESSED CABLE ENTRY SURFACE INSTALLATION 2 X 0 5 1 5 mm2 3 X 0 5 1 5 mm2 3 X 0 5 1 5 mm2 4 X 0 5 1 mm2 BASE STD T HT H03VV F H05VV F ...

Page 7: ...7 17 18 15 16 19 20 21 22 WIRING DIAGRAM PAGE 17 ...

Page 8: ...8 28 26 27 233 mm 225 mm RECESSED CABLE ENTRY RECESSED INSTALLATION 2 X 0 5 1 5 mm2 3 X 0 5 1 5 mm2 3 X 0 5 1 5 mm2 4 X 0 5 1 mm2 BASE STD T HT H03VV F H05VV F 9 40 mm 23 24 25 ...

Page 9: ...9 29 30 31 32 33 34 35 36 150mm ...

Page 10: ...10 37 38 39 42 43 40 41 WIRING DIAGRAM PAGE 17 ...

Page 11: ...11 44 CETO100C Vmax 45B PULL CORD PULL CORD ELECTRICAL WIRING max 45A CETO100 Vmax 5 5 45A CETO100 Vmin NO 5 CETO100C Vmin ...

Page 12: ... HY TIMER 46A 46B TIMER CETO100HTC Vmax 45D ROSSO RED ROUGE ROT ROSSO RED ROUGE ROT PULL CORD PULL CORD CETO100T HT Vmax ROSSO RED ROUGE ROJO ROSSO RED ROUGE ROJO CETO100T HT Vmin 45C 5 5 CETO100HTC Vmin ...

Page 13: ...13 MAINTENANCE CLEANING 47 48 49 51 50 ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...k to the retailer when purchasing a new equivalent type device Separate collection of decommissioned equipment for recycling treatment and environmentally compatible disposal helps to prevent negative effects on the environment and on health and promotes the recycling of the materials that make up the equipment Improper disposal of the product by the user may result in administrative sanctions as ...