3
TWIN unit
AWS 40 HP – E1J
AWS 50 HP – E1J
16+16 HP
16+20 HP
20+20 HP
16+25 HP
20+25 HP
25+25 HP
Capacity code of the connected GHP outdoor unit
P900
P1010
P1120
P1160
P1270
P1420
Rated cooling capacity
∗
kW
82,0
93,0
104,0
104,0
115,0
126,0
Water temperature (out – in)]
°C
7 – 11
7 – 11,5
7 – 12
7 – 11
7 – 11,5
7 – 12
Min. supply water temperature
°C
6
Rated heating capacity
∗∗
kW
95,0
107,5
120,0
122,5
135,0
150,0
Water temperature (out – in)
°C
45,5 – 41
45,5 – 40,5
45,5 – 40
45,5 – 41
45,5 – 40,5
45,5 – 40
Max. supply water temperature
°C
47
Flow rate
m
3
/h
19,0
24,0
Capacity modulation range cooling. (min-max)
kW
17,0 – 82,0
17,0 – 93,0
17,0–104,0
17,0–104,0
17,0–115,0
17,0–126,0
Capacity modulation range heating (min-max)
kW
19,8 – 95,0
19,8–107,5
19,8–120,0
19,8–122,5
19,8–135,0
19,8–150,0
Unit without
pump
(AWS E1J)
Power supply
V/Ph/Hz
230/1/50
Power consumption
W
250
Starting current
A
1,5
Plate heat exchanger pressure drop
kPa
33
33
33
46
46
46
Water
circuit
Water connections
Inch
2,5 (flange connection DN 65 – EN 1092 1/13)
Primary circuit pipe size
Inch
2,5 or higher
(Each AWS unit is fitted with a 2,5” Y strainer to be installed on the primary circuit)
Refrigerant
circuit
Refrigerant gas connection
(gas – liquid)
mm
2 x 28,6 – 2 x 18,0
GHP 1 – AWS
pipe size
(gas – liquido)
mm
28,6–15,88
***(19,05)
28,6–15,88
***(19,05)
28,6–15,88
***(19,05)
28,6–15,88
***(19,05)
28,6–15,88
***(19,05)
35,0–15,88
***(19,05)
GHP 2 – AWS
pipe size
(gas – liquido)
mm
28,6–15,88
***(19,05)
28,6–15,88
***(19,05)
28,6–15,88
***(19,05)
35,0–15,88
***(19,05)
35,0–15,88
***(19,05)
35,0–15,88
***(19,05)
Dimensions
and weight
Height
mm
915
Width
mm
710
Depth
mm
1.020
Weight
kg
230
Conectable GHP outdoor units
2
∗
Rated cooling capacity is measured according to the following conditions: water outlet temperature 7°C; outdoor temperature 35°C DB
∗∗
Rated heating capacity is measured according to the following conditions: water outlet temperature 47°C; outdoor temperature 7°C DB / 6°C WB
∗∗∗
If the distance between GHP and AWS exceeds 40 meters, install a pipe with the diameter indicated in brackets.
1.1
Installation prescriptions
CAUTION
Always foresee the installation of an emergency relief valve and a properly
dimensioned expansion vessel. These devices are not built in the AWS unit.
Where the storage tank should be installed lower than the AWS unit, foresee the
installation of a jolly valve at the higher point of the water piping.
Failure to observe these prescriptions could result in malfunction and/or damage to the
unit.
Always foresee the installation of a buffer tank, fitted with anti stratification
pipes, which size should be adequate to the AWS unit capacity.
Failure to observe these prescription could result in malfunction and/or damage to the
unit.
Always check that the Y-shape water filter (supplied with the unit) is installed on
the primary circuit return pipe. In case of multi units plants, install one filter each
AWS unit. Install the filter to not less than 50 cm from suction of the pump.
Failure to observe this prescription makes the warranty no longer valid and could result
in malfunction and/or damage to the unit.
WARNING
Welding, refrigerant gas and water piping installation should be always
performed by specialised technical personnel in accordance with instructions
and prescriptions mentioned in the present manual.
Failure to observe this prescription makes the warranty no longer valid and could result
in malfunction and/or damage to the YOSHI AWS unit.
1 AWS unit specifications
Summary of Contents for AXGP224E1
Page 1: ......
Page 2: ...2 ...
Page 4: ...4 ...
Page 7: ...7 1 2 External dimensions ...
Page 25: ...25 1 12 2 Wiring example AC 230 V single phase ...
Page 26: ...26 1 13 Power supply wiring procedure 1 13 1 Wiring instruction ...
Page 32: ...32 2 2 External dimensions ...
Page 40: ...40 2 7 Outline diagram of refrigerant piping 2 7 1 Combined installation ...
Page 41: ...41 2 7 2 Stand alone installation ...
Page 59: ...59 2 13 Power supply wiring procedure 2 13 1 Wiring instruction combined installation ...
Page 60: ...60 2 13 2 Wiring instruction stand alone installation ...
Page 62: ...62 2 14 2 Wiring example AC 230V single phase ...
Page 85: ...19 11 4 HVAC installation layout AWS E1 ...
Page 86: ...20 11 5 HVAC installation E1 with proportional distribution of consumption ...
Page 87: ...21 11 6 HVAC installation AWS E1J variable flow rate no hydraulic separator AHU ...
Page 88: ...22 11 7 HVAC installation AWS E1J variable flow rate with hydraulic separator fan coil ...
Page 93: ...27 NOTE ...
Page 94: ...28 ...
Page 95: ...29 ...
Page 96: ......
Page 109: ...13 7 2 Detailed wiring diagram ...
Page 115: ...19 11 4 HVAC installation AWS E1J TWIN ...
Page 116: ...20 11 5 HVAC installation E1J TWIN proportional distribution of consumption ...
Page 117: ...21 11 6 HVAC installation AWS E1J TWIN variable flow rate no hydraulic separator AHU ...
Page 118: ...22 11 7 HVAC installation AWS E1J TWIN variable flow rate with hydraulic separator fan coil ...
Page 123: ...27 NOTE ...
Page 124: ...28 ...
Page 125: ......
Page 126: ......