11—8 | SM YAZE218 1-A.2 GB
11—CONTROL SYSTEM
11.4.9.2 Floor/Ceiling Model
STANDBY INDICATOR
Lights up when the Air Conditioner is connected to power and is
ready for operation
OPERATE INDICATOR
1. Lights up during operation.
2. Blinks for 300 msec to announce that a R/C infrared signal has
been received and stored.
3. Blinks continuously during protections (according to the relevant
spec section).
TIMER INDICATOR
Lights up during Timer and Sleep operation.
FILTER INDICATOR
1. Lights up when Air Filter needs to be cleaned.
2. Blinks during Water Over Flow in PXD models. (Cf. Sect. 7.3)
COOLING INDICATOR
Lights up when system is switched to Cool Mode by using the
Mode Switch on the unit.
HEATING INDICATOR
Lights up when system is switched Heat Mode by using the Mode
Switch on the unit.
FAN MODE INDICATOR
Lights up in Fan Mode activated by local switches.
FAN SPEED INDICATORS
L -- Lights up when IFAN setting is Low.
M -- Lights up when IFAN setting is Medium.
H -- Lights up when IFAN setting is High.
A -- Lights up when IFAN setting is Auto.
TEMP. SETTING INDICATORS
Each one of the seven indicators indicates the following SPT:
18, 20, 22, 24, 26, 28, 30 [°C]. The odd number temperatures are
indicated by turning on the two adjacent indicators.
FAN SPEED BUTTON
Press this button to change the speed of the IFAN. Each pressing
change the speed in the sequence of: ... L
→
M
→
H
→
Auto
→
L
→
...
TEMP. SETTING UP BUTTON
Pressing this button increases the SPT by 1°C.
Note: The Max SPT is 30°C.
TEMP. SETTING DOWN BUTTON
Pressing this button decreases the SPT by 1oc. Note: The Min SPT
is 18oc.
MODE BUTTON
Every short pressing , the next operation mode is selected, in this order:
SB
→
Cool Mode
→
Heat Mode
→
SB
→
…
In long pressing system enters diagnostic mode.
POWER BUTTON
Toggle the unit between OPER & STBY modes.
RESET / FILTER BUTTON
For short pressing:
When Filter LED is on - turn off the FILTER INDICATOR after a
clean lter has been reinstalled.
When Filter LED is off – enable/disable the buzzer announcer, if selected.
In long pressing system enters set up mode (if in SB).
Summary of Contents for YAZE218
Page 11: ...4 1 SM YAZE218 1 A 2 GB 4 OUTLINE DIMENSIONS 4 OUTLINE DIMENSIONS 4 1 Indoor Unit HJD009 012 ...
Page 25: ...6 2 SM YAZE218 1 A 2 GB 6 OPERATING CURVES 6 1 2 Heating Technician Mode ...
Page 26: ...SM YAZE218 1 A 2 GB 6 3 6 OPERATING CURVES 6 1 3 Tubing Length correction Factor ...
Page 28: ...SM YAZE218 1 A 2 GB 8 1 8 WIRING DIAGRAMS 8 WIRING DIAGRAMS 8 1 YAZE218 Wiring Diagrams ...
Page 29: ...8 WIRING DIAGRAMS 9 1 SM YAZE218 1 A 2 GB 9 REFRIGERATION DIAGRAMS 9 1 YAZE218 Cooling Mode ...
Page 30: ...8 WIRING DIAGRAMS SM YAZE218 1 A 2 GB 9 2 9 2 YAZE218 Heating Mode ...
Page 77: ...14 1 SM YAZE218 1 A 2 GB 14 APPENDIX A 14 APPENDIX A INSTALLATION AND OPERATION MANUAL ...
Page 78: ...SERVICE MANUAL YAZE218 ...