SM YAZE218 1-A.2 GB | 11—29
11—CONTROL SYSTEM
Notes:
o
For the temperature display, when a thermistor is shorted, disconnected show
FLT, when it’s disabled show DIS.
o
It is possible to present a number between 999 and 99,999 by alternating between
two numbers (each number is presented for 1 second). The two numbers format
is (off)xx, yyy.
o
The compressor time is measured in hour’s units.
o
The modes: Cool, Heat, Dry, Fan Auto will be presented: CL, Ht, dr, FAn, AUt.
o
The current is the AC current of the unit.
o
The models A, b, C, and d will be presented -A-, -b-, -c-, and -d- respectively.
11.9 Jumper settings
ODU4
ODU3
ODU2
ODU1
ODU0
ODU
Model
Compressor Type
Single Split
Multi Split
ON
OFF
OFF
OFF
OFF
P
Sanyo
Mitsubishi
ON
OFF
OFF
OFF
ON
Q
Panasonic
Panasonic
ON
OFF
OFF
ON
OFF
R
ON
OFF
OFF
ON
ON
S
ON
OFF
ON
OFF
OFF
T
ON
OFF
ON
OFF
ON
U
ON
OFF
ON
ON
OFF
V
ON
OFF
ON
ON
ON
W
ON
ON
OFF
OFF
OFF
X
ON
ON
OFF
OFF
ON
Y
ON
ON
OFF
ON
OFF
Z
ON
ON
OFF
ON
ON
AA
ON
ON
ON
OFF
OFF
AB
ON
ON
ON
OFF
ON
AC
ON
ON
ON
ON
OFF
AD
ON
ON
ON
ON
ON
AE
Summary of Contents for YAZE218
Page 11: ...4 1 SM YAZE218 1 A 2 GB 4 OUTLINE DIMENSIONS 4 OUTLINE DIMENSIONS 4 1 Indoor Unit HJD009 012 ...
Page 25: ...6 2 SM YAZE218 1 A 2 GB 6 OPERATING CURVES 6 1 2 Heating Technician Mode ...
Page 26: ...SM YAZE218 1 A 2 GB 6 3 6 OPERATING CURVES 6 1 3 Tubing Length correction Factor ...
Page 28: ...SM YAZE218 1 A 2 GB 8 1 8 WIRING DIAGRAMS 8 WIRING DIAGRAMS 8 1 YAZE218 Wiring Diagrams ...
Page 29: ...8 WIRING DIAGRAMS 9 1 SM YAZE218 1 A 2 GB 9 REFRIGERATION DIAGRAMS 9 1 YAZE218 Cooling Mode ...
Page 30: ...8 WIRING DIAGRAMS SM YAZE218 1 A 2 GB 9 2 9 2 YAZE218 Heating Mode ...
Page 77: ...14 1 SM YAZE218 1 A 2 GB 14 APPENDIX A 14 APPENDIX A INSTALLATION AND OPERATION MANUAL ...
Page 78: ...SERVICE MANUAL YAZE218 ...