Engineering manual
112
2.9.3 Display introduction
F.
SIGNAL RECEIVER
G.
POWER INDICATOR
This LED will be in red whenever power is on.
Blinks for 3 seconds when heat mode is selected through mode
button.
H.
OPERATION INDICATOR
This LED will be in green during operation.
It will blink once when receiving message from remote controller
and keep blinking when there is any fault or protection.
It will blink 3 times when cool mode is selected through mode
button.
I.
TIMER INDICATOR
This LED will be in yellow when timing mode in remote
controllers is used.
It will blink after power off when Timers is set to show that timer
counting is lost.
J.
FILTER INDICATOR
This LED will be on when air filter requires cleaning.
F. MODE/RESET BUTTON
If filter LED is ON, a short pressing of the mode button will reset filter timer and turn off the filter clean LED.
If filter LED is OFF, mode button is used for forced operation mode in Cooling-Heating-OFF as circle.
If filter LED is OFF, long pressing the button, will entry diagnostic mode. Detail please contact with the technician.
If the air-conditioner can’t be operated by remote controller or LWC, it can be turned on
for cooling or heating, or completely turned off by every short pressing on MODE button (F)
on the display. The MODE button will change the operating status of the unit between
COOLING-HEATING-OFF. Long press the MODE can enters diagnostic mode.
Chart 2-25
Summary of Contents for KXV Series
Page 36: ...Engineering manual 36 Heating Chart 1 1 b...
Page 69: ...Engineering manual 69 1 3 2 Exploded view Unit body exploded view Chart 1 7...
Page 70: ...Engineering manual 70 Panel exploded view Chart 1 8...
Page 75: ...Engineering manual 75 1 4 Electric board wiring diagram Chart 1 9...
Page 93: ...Engineering manual 93 2 3 2 Exploded view Unit body exploded view Chart 2 5...
Page 94: ...Engineering manual 94 Panel exploded view Chart 2 6...
Page 99: ...Engineering manual 99 2 4 Electric board wiring diagram Chart 2 7...
Page 118: ...Engineering manual 118 3 3 2 Exploded view Chart 3 6...
Page 124: ...Engineering manual 124 3 4 Electric board wiring diagram Chart 3 7...
Page 143: ...Engineering manual 143 4 3 2 Exploded view DLV007 009 012 015 exploded view Chart 4 4...
Page 144: ...Engineering manual 144 DLV018 021 024 exploded view Chart 4 5...
Page 150: ...Engineering manual 150 4 4 Electric board wiring diagram Chart 4 6...
Page 166: ...Engineering manual 166 5 3 2 Exploded view Chart 5 4...
Page 167: ...Engineering manual 167 5 4 Electric board wiring diagram Chart 5 5...
Page 182: ...Engineering manual 182 6 3 2 Exploded view PNV007 009 012 exploded view Chart 6 5...
Page 183: ...Engineering manual 183 PNV015 018 021 exploded view Chart 6 6...
Page 189: ...Engineering manual 189 6 4 Electric board wiring diagram Chart 6 7...
Page 204: ...Engineering manual 204 1 Outdoor unit Model KBTU h Brand YAV112 38 2 YAV140 47 8 Airwell...
Page 207: ...Engineering manual 207 1 2 2 Exploded view YAV112 140 Chart 1 2...
Page 210: ...Engineering manual 210 1 3 Electric board wiring diagram Chart 1 3...
Page 212: ...Engineering manual 212 Chart 1 10 Chart 1 11 Chart 1 12 Chart 1 13 Chart 1 14 Unit mm...
Page 283: ...Engineering manual 283 Chart 3 4...
Page 294: ...Engineering manual 294 4 1 Appearance RC3i 1 A Q C E F G I D H J K L M N O P B...
Page 295: ...Engineering manual 295 A B C G D F E H I J K L M N O P Q RC7i 1...
Page 372: ...Engineering manual 372...
Page 376: ...Engineering manual 376 Click the value area of axis a dialog is shown to set the range of axis...