6.6.1. DHW USED WItH BoILER RELIEF
this configuration presumes that the boiler is not used to heat the dhW.
the compressor heats the dhW as much as possible then a water tank electric heater (dhWeh) will heat the water
further if required. configuration is l07 = "on"
1
3
2
1
1
1
1
1
1
5
6
7
1
12
13
9
5
6.6.2. SEt tEMPERAtURE UNAttAINABLE WItH tHE CoMPRESSoRS
When the
Aqu@ Scop Advance DCI
is in heating mode and a demand for dhW production appears, the
controller estimates whether it is possible to produce dhW with the compressor. if the dhW temperature is too
high, the appliance will remain in heating mode but the dhW electric heater will be able to operate in accordance
with the previous rules.
It is for this reason, as recommended above, that it is very important not to set
the DHW setpoints too high in order to avoid starting the electric heater too frequently.
6.6.3. APPLIANCE FAULt PREVENtING StARt-UP oF tHE CoMPRESSoR
if the compressor can not provide dhW production, then the electric heater will automatically take over the role
with the same setpoint.