off-peak input connected or default daily scheduling (comfort between 23h00 and 05h00 in the morning, eco
the rest of the time), set comfort and eco temperatures at 50°c and 10°c, no dhW production during the day.
0
10
20
30
40
50
60
TIME OF DAY
22 23 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 00 01
DHW SPT
DHW T.
DHW TEMPERATURE (°C)
No restart during the day,
Eco setpoint at 10°C.
DHW OFF at Comfort SPT + 2°C
Temp. exceeded due to system inertia.
6.4. "qUICK HEAt-UP" FUNCtIoN
this function can be used when dhW is needed in a hurry and the tank is not hot enough as, for example when
you return from holidays with the
Aqu@ Scop Advance DCI
in Main oFF mode or even switched off from the
power supply (not recommended).
When the "QuicK heat-uP" function is activated, the aim is to heat the dhW as rapidly as possible. the
Aqu@ Scop Advance DCI
’s controller acts in the following manner :
²
the system is switched to forced dhW mode, and ignores the room temperature conditions,
²
the dhW setpoint changes to the comfort setpoint, even is the current mode was eco,
²
the electric heater is authorised to start at the same time as the compressor to provide extra heating
capacity.
o13 = on
VALUE
o13
VALUE
o12
VALUE
o11
VALUE
o10
VALUE
o09
VALUE
o08
VALUE
o07
VALUE
o06
VALUE
o05
VALUE
o04
VALUE
o03
VALUE
o02
VALUE
o01
Increases the value
Decreases the value
Stores the new value
+
Exits without changing the value
+
ECS
+
PAr
+
LWT / OFF
When the dhW reaches the se 2°c, the "QuicK heat-uP" function will be automatically deactivated and
the
Aqu@ Scop Advance DCI
will return to its original operating mode.