AirSynergy3 Equipment Installation Guide
Page 61 | Commercial in Confidence SYN-UG-018
20cm
Or
r cm, where r = √ (PG/4πS)
P: power input to antenna(s) in mW
G: numeric gain of antenna relative to isotropic radiator
S: power density in mW/cm2 = 1 mW/cm2
The device has two antenna ports, so safe distance from the antenna shall be the greater
of:
20 cm or √ (2*PG/4πS)
Which gives
20 cm or √ (0.16*P*G) cm.