AirSynergy3 Equipment Installation Guide
Page 52 | Commercial in Confidence SYN-UG-018
Figure 69 - Back to Back AirSynergy mounted on pole with 4 mounting straps
Mount the assembly on the universal mounting bracket and secure the flange nuts. The GPS antenna
and front mount antenna if used can be fitted before or after mounting to the pole depending on ease
of access.
In cases where no front mount antenna is fitted, an extended sun shield is available as an accessory
item and should be fitted. The fitting method is the same as the standard sun shield with 3 fixings on
each side of the front AirSynergy unit.
Follow the normal procedures for the connection of power supply units and drop cabling to each of the
back to back mounted AirSynergy units.