6. Electrical Wiring
• Turn OFF the main power switch to the indoor unit and the outdoor unit before electrical wiring work or a
periodical check is performed.
• Check to ensure that the indoor
tan
and the outdoor
tan
have stopped before electrical wiring work or a
periodical check is performed.
• Protect the wires, drain pipe, electrical parts , etc. from rats or other small animals. lt not protected, rats may
gnaw at unprotected parts and at the worst, a tire will occur.
• Check the item below before turning ON the main switch.
e
Tighten screws according to the following torque.
M3.5: 1.2N.m
M5:2.0~2.4N.m
A.CAUTION
• Wrap the accessory packing around the wires, and plug the wiring connection hole with the seal material to
protect the product from any condensate water or insects.
• Tightly secure the wires with the cord clamp inside the indoor unit.
• Secure the cable
ot
the remote control switch using the cord clamp inside the electrical box.
6. 1 General Check
(1) Make sure that the field-selected electrical components(main power switches, circuit breakers, wires, conduit
connectors and wire terminals) have been properly selected according to the electrical data given in
"7.Electrical lnstallation". Make sure that the components comply with National Electrical Code(NEC).
(2) Check to ensure that the power supply voltage is within ±10%
ot
the rated voltage.
(3) Check the capacity
ot
the electrical wires. lt the power source capacity is too low, the system cannot be started
due to the voltage drop.
(4) Check to ensure that the ground wire is connected.
(5) Power Source Main Switch lnstall a multi-pole main switch with a space of 3.5mm or more between each
phase.
6. 2 Electrical Wiring Connection
The intermediate connection between the indoor unit and the air panel should be referred to in the lnstallation
Manual for Air Panel'.
(1) Connect the power supply and earth wires to the terminals in the electrical box.
(2) Connect the wires between the indoor unit and the outdoor unit to the terminals in the electrical box.
Electrical Wiring Diagram
Outdoor unit
Terminal
lndoor unit
Terminal
54
Summary of Contents for ORIA 18 INT
Page 2: ...MANUAL DE USUARIO E INSTALACIÓN ESPAÑOL CASSETTE ORIA 18 INT ORIA 24 INT ORIA 36 INT ORIA ...
Page 3: ...2 ...
Page 4: ...3 ...
Page 5: ...4 5 12 13 13 13 14 15 17 17 18 18 23 24 26 27 27 ...
Page 29: ...28 ...
Page 30: ...OWNER S AND INSTALLATION MANUAL ENGLISH CASSETTE ORIA 18 INT ORIA 24 INT ORIA 36 INT ORIA ...
Page 32: ...31 ...
Page 33: ...32 33 40 41 41 41 42 43 45 45 46 46 46 52 54 55 55 ...
Page 57: ...56 ...
Page 58: ...PORTUGUÊS MANUAL DO UTILIZADOR E INSTALAÇÃO CASSETTE ORIA 18 INT ORIA 24 INT ORIA 36 INT ORIA ...
Page 59: ...58 ...
Page 60: ...59 ...
Page 61: ...60 61 68 69 69 69 70 71 73 73 74 74 74 80 82 83 83 ...
Page 85: ...84 ...
Page 86: ...ITALIANO MANUALE DI UTENTE E INSTALLAZIONE CASSETTE ORIA 18 INT ORIA 24 INT ORIA 36 INT ORIA ...
Page 87: ...86 ...
Page 88: ...87 ...
Page 89: ...88 89 96 97 97 97 98 99 101 101 102 102 102 108 110 111 111 ...
Page 90: ...89 ...