6
The IS-IPRY has 4 relays that can be programmed to trigger while calling, while in communication, or while calling and
communicating with a specific station. The relays can also be programmed for door release.
Set the IS-IPRY for use with the IX Series (refer to page 5).
From the
DEVICE CONFIGURATION
screen, click
APPLICATION SETUP
.
APPLICATION SETUP button
Enter the
station number
of the station to be associated with the relay. Select the relay condition from the
Relay Action
drop down menu.
Click on
Apply Settings
then click
Reboot
to restart the adaptor with the saved changes.
When the entered station is active, the associated relay will trigger based on the Relay Action settings.
Relay Action options:
• Door Release - Normally-Open
• Door Release - Normally-Closed
•
Active while Calling from Source
•
Active while Communicating
•
Active during Calling and Communicating
The IX Series allows for door release partitioning. When the IS-IPRY relay action is set for door release, the relay
will be triggered only if door release is allowed on the station. To set door release partitioning, refer to
Door Release
Settings
under the
Function Settings
tree in the IX Support Tool.
When the relay action is set for the “Door Release” options, the relay on the IS-IPRY will trigger when the associated
station is calling or communicating and its door release contact is triggered.
When the relay action is set for any of the “Active While” options, the relay will trigger when the associated station calls
or communicates at any priority level.
Relay will trigger when the associated station’s door release contact is triggered.
Relay will trigger when the associated station calls or communicates.
}
}
IX Series:
Relay Output Programming