44
Chapter 4. BMC Configuration Settings
J4078-01 User Manual
4�3�3 SES Inband Features
To ensure proper function, high performance, and durability, J4078-01 has
implemented SCSI Enclosure Services to monitor the status of power supply, system
cooling fan, and working temperature. It also has indicators to deliver the status of
fail devices such as power supply or cooling fan. You can get the information directly
from the front indicators to know how your enclosure works.
For detailed information, please visit
http://www.t10.org
If you are a member of the T10 working group, the Standard which controlled by T10
technical committee, could be found at
http://www.t10.org/cgi-bin/ac.pl?t=f&f=ses2r19a.pdf
4.3.3.1 SES Pages
00h - List of supported diagnostic pages
01h - SES configuration
02h - SES enclosure control / enclosure status
04h – SES String In
05h – SES Threshold Out / In
07h - SES element descriptor
0Ah - SES additional element
0Eh - SES download microcode control / SES download
microcode status
83h – SES Vendor specific page : Canister Number
4.3.3.2 SES Elements
02h - Power Supply
03h - Cooling
04h - Temperature Sensor
0Eh - Enclosure
12h - Voltage
17h - Array Device