Chapter 4. BMC Configuration Settings
J4078-01 User Manual
4.3.2.2 How to get all revisions in AIC SAS 12G Expander
( A ) Expander firmware revision
cmd> rev
( B ) Expander configuration revision
cmd> showmfg
( C ) MCU firmware revision or sensor information (MCU firmware revision is reported
by Hub only)
cmd> sensor
4.3.2.3 How to configure enclosure address (HUB only)
( A ) Get the current enclosure address
cmd> enclosure_addr
Enclosure Address: 0x500605B0000272BF
( B ) Set the enclosure address with 0x500605B0000272BF. The new
setting will take effect after reset.
cmd> enclosure_addr 500605B0000272BF
cmd> reset
4.3.2.4 How to configure standby timer for all disk drives (EDGE only)
This feature is applicable for SAS/SATA drives. Standby timer is in units of minutes.
Setting standby timer with 0 minute disables this feature.
( A ) Get current standby timer
cmd> standby_timer
Standby Timer : 0 minutes
( B ) Set the standby timer with 10 minutes. The new setting will take effect after reset.
cmd> standby_timer 10
cmd> reset
NOTE
This function is not recommended to use with RAID card due to the RAID card
limitation.