47
Chapter 4. BMC Configuration Settings
J4078-01 User Manual
4.3.3.4 Implementation on SES Elements
Only the fields highlighted in green are supported.
Power Supply Element
(A) Power Supply Control Element
BYTE/BIT
7
6
5
4
3
2
1
0
0
COMMON CONTROL
SELECT PRDFAIL DISABLE
RST
SWAP
Reserved
1
RQST
IDENT
Reserved
2
Reserved
3
Reserved RQST
FAIL
RQST ON
Reserved
Field
Value
RQST ON
Please refer to section “SES Element Control Functions” for details.
(B) Power Supply Status Element
BYTE/BIT
7
6
5
4
3
2
1
0
0
COMMON STATUS
Reserved PRDFAIL DISABLE SWAP
ELEMENT STATUS CODE
1
IDENT
Reserved
2
Reserved
DC OVER
VOLTAGE
DC
UNDER
VOLTAGE
DC
OVER
CURRENT
Reserved
3
HOT
SWAP
FAIL
RQSTED
ON
OFF
OVERTMP
FAIL
TEMP
WARN
AC FAIL DC FAIL
Field
Value
ELEMENT
STATUS CODE
OK: No failure or warning conditions detected
CRITICAL: FAIL bit is set due to one or more failure condition
FAIL
A failure condition is detected
RQSTED ON
1: On
0: Off
OFF
1: Off
0: On
AC FAIL
A failure condition is detected
DC FAIL
A failure condition is detected