50
Chapter 4. BMC Configuration Settings
J4078-01 User Manual
Enclosure Element
(A) Enclosure Control Element
BYTE/BIT
7
6
5
4
3
2
1
0
0
COMMON CONTROL
SELECT PRDFAIL DISABLE
RST
SWAP
Reserved
1
RQST
IDENT
Reserved
2
POWER CYCLE
REQUEST
POWER CYCLE DELAY
3
POWER OFF DURATION
REQUEST
FAILURE
REQUEST
WARNING
Field
Value
POWER CYCLE
REQUEST
Please refer to section “SES Element Control Functions” for
details.
POWER CYCLE
DELAY
Please refer to section “SES Element Control Functions” for
details.
POWER OFF
DURATION
Please refer to section “SES Element Control Functions” for
details.
REQUEST
FAILURE
Please refer to section “SES Element Control Functions” for
details.
REQUEST
WARNING
Please refer to section “SES Element Control Functions” for
details.
(B) Enclosure Status Element
BYTE/BIT
7
6
5
4
3
2
1
0
0
COMMON STATUS
Reserved PRDFAIL DISABLE SWAP
ELEMENT STATUS CODE
1
IDENT
Reserved
2
TIME UNTIL POWER CYCLE
FAILURE
INDICATION
WARNING
INDICATION
3
REQUEST POWER OFF DURATION
FAILURE
REQUESTED
WARNING
REQUESTED
Field
Value
ELEMENT
STATUS CODE
OK
TIME UNTIL
POWER CYCLE
The time until the enclosure's power is scheduled to be off.
0: No Power cycle scheduled,
1~60: The enclosure is scheduled to begin a power cycle after
the indicated number of minutes.
63: The enclosure is scheduled to begin a power cycle after
zero minute.