USE OM - JANUARY 2017
25
Table B3: DOE HSVTC Test Data
DOE HSVTC Test Data
Comments
Item
Value
Indoor Power, watts
Mean System Net Capacity, A-test, Btu/h
Mean of the values measured during HSVTC testing
Outdoor Unit Gross Capacity, A-test,
Btu/h
Calculated value; Mean system net + indoor power converted to
Btu/h
Mean System Net Capacity B-test, Btu/h
Mean of the values measured during HSVTC testing
Outdoor Unit Gross Capacity, B-test,
Btu/h
Calculated value; Mean system net + indoor power converted to
Btu/h
Mean System Power A-test, watts
Mean of the values measured during HSVTC testing
Outdoor Unit System Power, A-test, watts
Calculated value; Mean system net
– indoor power
Mean System Power B-test, watts
Mean of the values measured during HSVTC testing
Outdoor Unit System Power, B-test, watts
Calculated value; Mean system net
– indoor power
Mean Indoor Liquid Temperature, A-test,
F
Mean of the values measured during HSVTC testing
Mean Indoor Suction Pressure, A-test,
psig
Mean of the values measured during HSVTC testing
Mean Evaporator Temperature, A-test F
Input or Calculated value; Calculation based on saturation
temperature for pressure above
Mean Indoor Suction Pressure B-test, psig
Mean of the values measured during HSVTC testing
Mean Evaporator Temperature, B-test F
Input or Calculated value; Calculation based on saturation
temperature for pressure above
Item
Value
A-Test
Evaporator Temperature, T1, F
Saturated suction temperature, evaporator leaving
Condenser Capacity, A-test, @ T1, btuh
Includes pressure loss of interconnecting lines with addition of indoor
power converted to btuh
Condenser Power, A-test, @ T1, watts
Compressor & OD air mover power only
Evaporator Temperature, T2, F
Saturated suction temperature, evaporator leaving
Condenser Capacity, A-test, @ T2, btuh
Includes pressure loss of interconnecting lines with addition of indoor
power converted to btuh
Condenser Power, A-test, @ T2, watts
Compressor & OD air mover power only
B-Test
Evaporator Temperature, T1, F
Saturated suction temperature, evaporator leaving
Condenser Capacity, B-test, @ T1, btuh
Includes pressure loss of interconnecting lines with addition of indoor
power converted to btuh
Condenser Power, B-test, @ T1, watts
Compressor & OD air mover power only
Evaporator Temperature, T2, F
Saturated suction temperature, evaporator leaving
Condenser Capacity, B-test, @ T2, btuh
Includes pressure loss of interconnecting lines with addition of indoor
power converted to btuh
Condenser Power, B-test, @ T2, watts
Compressor & OD air mover power only
Table B4: Simulation Inputs for High or Single Stage
Simulation Inputs
Comments