Light Sensor Calibration
The light sensor has a simple zero calibration which is designed to calibrate the sensor for darkness.
Before calibrating the light sensor zero, ensure the light sensor is in total darkness. Allow at least 60 seconds for the light
reading to fully settle and stabilize.
Touch Panel
Access the sensor calibration menu from “Main Menu -> System -> Analog Sensors -> Sensor Cal.”
Software
Press the calibration button for the light sensor to calibrate.
Software Features
The GC-Pro comes with free computer software which allows full remote monitoring and control of the GC-Pro, as well as some
additional features, including:
Data-logging to CSV files
Graphical trending up to 48 hours
Email alerts from alarms
Video camera monitoring and image logging
Upload/Download settings files to/from controllers
Press “Light” to calibrate the light
sensor.
Zero: Press “Set Zero” to calibrate the
light sensor zero in darkness.