© 2013 Agrowtek Inc.
www.agrowtek.com
| 83 Ambrogio Dr Suite H Gurnee, IL 60031 | [email protected]
44
Touch Panel
Access the “System” menu from the “Main” menu.
Software
The units settings are accessed in the “Controller -> System Settings” window.
System Timers
The GC-Pro has several built-in system timers:
System Start-up Delay: Delay timer that starts at power-up and disables all outputs until the time has elapsed. This can
prevent immediate re-starting of outputs in a power glitch or allow time for sensor readings to stabilize before starting.
Output Sequence Delay: Delay time that separates outputs from starting at the same time. If multiple outputs are activated
simultaneously (such as when changing between day/night or at system start-up) the controller will separate the starting of
the outputs by the delay time. This reduces surges in the electrical loading.
Hot-Fire Delay: The outputs assigned to the lighting controls are monitored by the controller; if they turn off automatically,
manually, or if the power is interrupted, the controller will prevent them from operating until the hot-fire delay time has
elapsed.
Press “System Units” to access the units
menu. System password required.
Toggle units or select a sub-menu.