$JLOHQW3DWLHQW&DUH6\VWHP,QWHUIDFH
When connected to the Agilent patient care system network, or Agilent monitoring network
(SDN), the Agilent V24/V26 Series is capable of receiving and displaying current vital signs,
waves and alarms from other bedsides on the network. The Agilent monitoring network
(SDN) connection also allows connectivity to a Central Station and centralized arrhythmia
systems. The instrument has one Agilent monitoring network (SDN) connector (upstream
only); therefore it must be the last instrument on an Agilent monitoring network (SDN)
branch.
The Agilent monitoring network (SDN) interface subsystem consists of the physical
connection to the Agilent monitoring network (SDN) network and controlling firmware
resident on the System Board. (Your configuration may use an Agilent monitoring network
(SDN) daughter card. Refer to
$SSHQGL[$
for more information.) When the Agilent V24/
V26 Series is connected to the Agilent monitoring network (SDN), digitized patient
information is transmitted serially at regular intervals (called poll cycles) over branch cables
to the System Communications Controller (SCC). The SCC sequentially receives,
synchronizes and rebroadcasts the digitized patient information to all the instruments
connected to the Agilent monitoring network (SDN). Patient data is received for use by each
instrument by way of the Agilent monitoring network (SDN) interface circuitry resident in
each instrument.
Warning:
Connecting the Agilent monitoring network (SDN) cable when the product
is powered on is not supported. Error codes and Agilent monitoring network
(SDN) interface lock-up may occur. Power cycling the product will recover
the product. No permanent damage will result. To prevent unintentional
disruption in monitoring, be sure the SDN interface cable is properly
secured at both ends when connecting to the Agilent monitoring network
(SDN).
561HWZRUN
The optional RS-232 interface has one port that permits either MECIF connectivity, M1026A
AGM compatibility, connection to a personal computer, or local printing capability.
3DWLHQW'DWD0DQDJHPHQW
The Agilent V24/V26 Series provides Patient Data Management software, allowing you to:
• manage patient information
• view patient data in graphs or tables
• print patient information reports via an Agilent central station or local RS-232 printer.
:KDWLVWKH$JLOHQW
SDWLHQWFDUHV\VWHP"
$JLOHQWSDWLHQWFDUH
V\VWHPDOVRNQRZQDV
$JLOHQWPRQLWRULQJ
QHWZRUN6'1LVD
ORFDODUHD
FRPPXQLFDWLRQV
QHWZRUNGHVLJQHGWR
VKDUHSDWLHQWGDWD
DPRQJEHGVLGH
LQVWUXPHQWV&HQWUDO
6WDWLRQVUHFRUGHUV
SULQWHUVFRPSXWHU
V\VWHPVDQGRWKHU
LQIRUPDWLRQV\VWHPV
FRQQHFWHGWRWKH$JLOHQW
PRQLWRULQJQHWZRUN
6'1
7KH$JLOHQWPRQLWRULQJ
QHWZRUN6'1LVD
GLJLWDOFRPPXQLFDWLRQV
QHWZRUNWKDWDOORZV
UHDOWLPHWUDQVIHURI
GLJLWDOL]HGSDWLHQWGDWD
EHWZHHQWKHVH
LQVWUXPHQWV7KH
FRPPXQLFDWLRQV
SURWRFROGDWD
IRUPDWWLQJDQG
KDUGZDUH
LPSOHPHQWDWLRQ
DFFRPPRGDWHVDYDULHW\
RIFRPPXQLFDWLRQV
QHHGVIRUSUHVHQWDQG
IXWXUHH[SDQVLRQ
Summary of Contents for M1205A V24
Page 1: ...3DUW 1R 0 3ULQWHG XQH 7KLUG GLWLRQ JLOHQW 0 9 DQG 9 6HUYLFH XLGH...
Page 4: ......
Page 12: ...12 Contents...
Page 16: ...JLOHQW 0 9 9 6HULHV 6HUYLFH XLGH 2YHUYLHZ...
Page 214: ...JLOHQW 0 9 9 6HULHV 6HUYLFH XLGH 5HSDLULQJ WKH JLOHQW 0RGHO 9 Repairing the Agilent Model V24...
Page 301: ...JLOHQW 0 9 9 6HULHV 6HUYLFH XLGH 5HSODFHPHQW 3DUWV Replacement Parts 17 4 3 7 12 5 6 26...
Page 358: ...QGH...