Front-Panel Menu/Key Reference
This section gives an overview of the front-panel keys/menus. The menus are
designed to automatically guide you through all parameters required to
configure a particular function or operation.
1 Output1 selection key
Select the
output1 voltage and current to be controlled and
monitored on the display.
2 Output2 selection key
Select the
output2 voltage and current to be controlled and
monitored on the display.
3 Low voltage range selection key
Selects the low voltage range and allows its full
rated output to the output terminals.
4 High voltage range selection key
Selects the high voltage range and allows its full
rated output to the output terminals.
5 Overvoltage protection key
Enables or disables the overvoltage protection function,
sets trip voltage level, and clears the overvoltage condition.
6 Display limit key
Shows voltage and current limit values on the display and allows
the knob adjustment for setting limit values.
7 Resolution selection keys
Move the flashing digit to the right or left. Adjust the
scrolling speed of the text being displayed in the View menu.
8 Voltage/Current adjust selection key
Selects the knob control function for voltage
or current adjustment.
9 Knob
Increases or decreases the value of the flashing digit by turning clockwise or
counter clockwise.
10 Output On/Off key
Enables or disables the power supply output. This key toggles
between on and off.
11 I/O Configuration / Secure key
3
Configures the power supply for remote interfaces
/ or secures or unsecures the power supply for calibration.
12 View menu / Calibrate key
2
Views the error codes and the text of the error message,
calibration string, and system firmware revision / or enables calibration mode.
13 State storage menu / Local key
1
Stores up to five power supply’s states and assigns
a name to each of the storage locations / or returns the power supply to local mode
from remote interface mode.
14 Stored state Recall menu
Recalls a stored operating state from location ‘‘1’’ through
‘‘5’’ and resets the power supply to the power-on state (*RST command).
15 Tracking enabling/disabling key
Enable / disable the track mode of the outputs.
1
The key can be used as the ‘‘
Local
’’ key when the power supply is in the remote
interface mode.
2
You can enable the ‘‘calibration mode’’ by holding down this key when you turn on the
power supply.
3
You can use it as the ‘‘Secure’’ or ‘‘Unsecure’’ key when the power supply is in the
calibration mode.
Summary of Contents for E364XA Series
Page 9: ...8...
Page 15: ...14 Contents Contents...
Page 16: ...1 Quick Start...
Page 26: ...2 General Information...
Page 38: ...3 Front Panel Operation and Features...
Page 70: ...4 Remote Interface Reference...
Page 122: ...5 Error Messages...
Page 133: ...Chapter 5 Error Messages Calibration Errors 132...
Page 134: ...6 Application Programs...
Page 145: ...Chapter 6 Application Programs Example Program for Excel 97 144...
Page 146: ...7 Tutorial...
Page 157: ...Chapter 7 Tutorial Remote Programming 156...
Page 158: ...8 Specifications...
Page 166: ...Appendix Service Information...
Page 175: ...Appendix Service Information General Disassembly 174 General Disassembly...
Page 207: ......
Page 208: ......
Page 209: ......
Page 210: ......
Page 211: ......
Page 212: ......
Page 213: ......
Page 214: ......
Page 215: ......
Page 216: ......
Page 217: ......
Page 218: ......