Chapter 4 Remote Interface Reference
Using the APPLy Command
84
Using the
APPLy
Command
The
APPLy
command provides the most straightforward method to program the
power supply over the remote interface. You can select the output voltage and current
in one command.
APPLy {
<voltage>
| DEF | MIN | MAX}[,{
<current>
| DEF | MIN | MAX}]
This command is combination of
VOLTage
and
CURRent
commands.
The
APPLy
command changes the power supply’s output to the newly programmed
values only if the programmed values are valid within the presently selected range.
An execution error will occur if the programmed values are not valid within the
selected range.
You can substitute ‘‘
MINimum
’’, ‘‘
MAXimum
’’, or ‘‘
DEFault
’’ in place of a
specific value for the
voltage
and
current
parameters. For more details of parameters,
see Table 4-1 for each model.
If you specify only one parameter of the
APPLy
command, the power supply regards
it as voltage setting value.
APPLy?
Query the power supply’s present voltage and current setting values and returns a
quoted string. The voltage and current are returned in sequence as shown in the sample
string below (the quotation marks are returned as part of the string).
‘‘8.00000,3.00000’’
(E3646A model)
Summary of Contents for E3646A
Page 2: ...2...
Page 16: ...16 Contents Contents...
Page 17: ...1 Quick Start...
Page 27: ...2 General Information...
Page 39: ...3 Front Panel Operation and Features...
Page 72: ...Chapter 3 Front Panel Operation and Features Calibration Overview 72...
Page 73: ...4 Remote Interface Reference...
Page 125: ...5 Error Messages...
Page 136: ...Chapter 5 Error Messages Calibration Errors 136...
Page 137: ...6 Application Programs...
Page 148: ...Chapter 6 Application Programs Example Program for Excel 97 148...
Page 149: ...7 Tutorial...
Page 160: ...Chapter 7 Tutorial Remote Programming 160...
Page 161: ...8 Specifications...
Page 169: ...Appendix Service Information...
Page 178: ...Appendix Service Information General Disassembly 178 General Disassembly...
Page 210: ......