
5
-
56
STATus Subsystem
When queried, the largest value that can be returned is
32767. This is because the most-significant register bit
cannot be set true.
Example
OUTPUT 720;”:STATUS:OPER:PTRansition 16”
:STATus:PRESet
Presets the enable registers and the PTRansition and
NTRansition filters.
Attribute Summary
Preset
State: none
*RST State: none
SCPI Compliance: standard
Command Only
Description
The PRESet command is defined by SCPI to affect the
enable register. If you want to clear all event registers
and queues, use the *CLS command.
Example
OUTPUT 720;”:STATUS:PRESET”
Status Node
Preset Value
Operation enable register
0
Questionable enable register
0
PTRansition filters
32767
NTRansition filters
0
Summary of Contents for 86121A
Page 2: ...User s Guide Agilent 86121A WDM Channel Analyzer ...
Page 7: ......
Page 10: ...Chapter 1 Getting Started ...
Page 21: ......
Page 24: ...Agilent 86121A Front and Rear Panels 2 3 Agilent 86121A Front and Rear Panels ...
Page 25: ...2 4 Agilent 86121A Front and Rear Panels ...
Page 27: ...2 6 WDM Channel Analyzer Display The S N with Averaging display ...
Page 32: ...The Softkeys 2 11 The Setup menu ...
Page 33: ...2 12 The Softkeys The Disk menu The Printer menu ...
Page 35: ...2 14 Changing the Printer Paper Changing the Printer Paper ...
Page 37: ......
Page 191: ......
Page 205: ...7 14 Regulatory Information Declaration of Conformity ...
Page 239: ......