Laminated Stiffener (2 Ga) with an Insert (10–12 Ga) to a Laminated
Base Stiffener (2 Ga) with a Base Insert (2–12 Ga)
Reference the following information when connecting a laminated stiffener and insert (CTS-4008XX and
CTS-4010XX) to a laminated base stiffener and base insert (CTS-4034XX and CTS-4037XX).
A
Laminated stiffener (CTS-4008XX)
B
Insert (CTS-4010XX)
C
Laminated base stiffener (CTS-4034XX)
D
Base insert (CTS-4037XX)
E
3/8 x 1 in. flange bolt (S-7485)
F
3/8 in. flange nut (S-9426)
G
Completed assembly
NOTE:
Only place bolts where holes in the stiffeners align
with holes in the sidewall sheet.
Base Stiffener (10–16 Ga) to a Base Boot
Reference the following information when connecting a base stiffener (CTS-4038XX) to a base boot
(CTS-4046XX).
A
Base stiffener (CTS-4038XX)
B
Base boot (CTS-4046XX)
C
3/8 x 1 in. flange bolt (S-7485)
D
3/8 in. flange nut (S-9426)
E
Completed assembly
NOTE:
Only place bolts where holes in the stiffeners
align with holes in the sidewall sheet.
52