Stiffeners Splice
Use the following information to determine the gauge of the splice needed to connect the stiffeners.
Figure 6-5
Stiffener splice
Call Out
Part Number
Description
Length
Available Gauges
A
CTS–4035XX
Stiffener splice
9.938 in. (25.24
cm)
12, 14
B
CTS-4073XX
Stiffener splice
15.906 in. (40.40
cm)
10
Use the following chart to determine the gauge of the splice, which is determined by the gauge of the stiff-
eners that are being connected. If connecting a heavier gauge to a lighter gauge stiffener, always use the
heavier gauge splice for the 13 to 12, 8 to 6, and 2 to 0 gauge connections.
For example:
If connecting a 13 gauge stiffener to a 12 gauge stiffener, use the 12 gauge splice. If con-
necting an 8 gauge stiffener to a 6 gauge stiffener, use the 10 gauge splice. If connecting a 2 gauge stiff-
ener to a 0 gauge stiffener, use the 8 gauge splice.
Table 6-3
Splice Usage
Stiffener Gauge
Splice Gauge
10 Gauge
12 Gauge
14 Gauge
18
X
17
X
16
X
15
X
14
X
13
X
12
X
11
X
10
X
9
X
8
X
6
X
5
X
2
X
0
Pneg-4460A
60 Ft Diameter 40-Series Bins
43