![Aerotech Ensemble CP Series Hardware Manual Download Page 95](http://html1.mh-extra.com/html/aerotech/ensemble-cp-series/ensemble-cp-series_hardware-manual_2863035095.webp)
94
Chapter 3
www.aerotech.com
TB202
OUTPUT
TB202-1
OPTOOUT 7
TB202-10
OPTOOUT 6
TB202-9
OPTOOUT 5
TB202-8
OPTOOUT 4
TB202-7
OUTPUT COMMON -
5-24 VDC
+
-
EACH OUTPUT 60 mA MAXIMUM
+
LOAD
-
+
LOAD
-
+
LOAD
-
+
LOAD
-
DIODE REQUIRED ON EACH OUTPUT THAT DRIVES AN INDUCTIVE DEVICE (COIL), SUCH AS A RELAY.
CONNECTION REQUIRED
TB202-2
1
3
2
1
3
2
OPTOOUT 3
TB202-6
OPTOOUT 2
TB202-5
OPTOOUT 1
TB202-4
OPTOOUT 0
TB202-3
OUTPUT SWITCH
DEVICES
+
LOAD
-
+
LOAD
-
+
LOAD
-
+
LOAD
-
Figure 3-8:
Outputs Connected in Current Sourcing Mode
CONNECTION REQUIRED
1
TB202
OUTPUT
TB202-1
OPTOOUT 7
TB202-10
OPTOOUT 6
TB202-9
OPTOOUT 5
TB202-8
OPTOOUT 4
TB202-7
OUTPUT COMMON -
5-24 VDC
+
-
+
LOAD
-
+
LOAD
-
+
LOAD
-
+
LOAD
-
TB202-2
1
3
2
EACH OUTPUT 60 mA MAXIMUM
2
DIODE REQUIRED ON EACH OUTPUT THAT DRIVES AN INDUCTIVE DEVICE (COIL), SUCH AS A RELAY.
3
OPTOOUT 3
TB202-6
OPTOOUT 2
TB202-5
OPTOOUT 1
TB202-4
OPTOOUT 0
TB202-3
OUTPUT
SWITCHES
+
LOAD
-
+
LOAD
-
+
LOAD
-
+
LOAD
-
Figure 3-9:
Outputs Connected in Current Sinking Mode
Ensemble CP
-IO Expansion Board