![Aerotech Ensemble CP Series Hardware Manual Download Page 30](http://html1.mh-extra.com/html/aerotech/ensemble-cp-series/ensemble-cp-series_hardware-manual_2863035030.webp)
Installation and Configuration
Ensemble CP
Drive
AC1
28V
Internal
Thermal
Switch
Integral Fuse
3.15A Slow-Blow
0V
0V
0V
100V
100V
115V
115V
F1-OUT
Frame Ground
F1-IN
SAFETY
AC LO
115 VAC
50/60 HZ
INPUT
Secondary = 28 VAC (40 VDC Bus)
AC HI
0V
28V
AC2
AC1
AC2
Mo
to
r
Su
p
p
ly
C
o
n
tro
l
Su
p
p
ly
6
6
1
4
1
3
5
Drive
AC1
28V
Internal
Thermal
Switch
Integral Fuse
3.15A Slow-Blow
0V
0V
0V
100V
100V
115V
115V
F1-OUT
Frame Ground
F1-IN
SAFETY
AC LO
230 VAC
50/60 HZ
INPUT
Secondary = 28 VAC (40 VDC Bus)
AC HI
0V
28V
AC2
AC1
AC2
Mo
to
r
S
u
p
p
ly
C
o
n
tro
l
S
u
p
p
ly
6
6
2
4
2
3
5
1. For 100 VAC primary input, parallel the 100 VAC taps and leave the 115 VAC taps unterminated.
2. For 200 VAC primary input, series the 100 VAC taps and leave the 115 VAC taps unterminated.
3. When using an isolation transformer, earth grounding of the AC2 input tap reduces electrical and audible noise emissions
and provides increased servo performance.
4. Transformer Primary Wiring: 0.8 mm
2
(#18 AWG) 300 V wire.
5. Transformer Secondary Wiring: 1.3 mm
2
(#16 AWG) 300 V wire.
6. AC line filters are for CE compliance. Filters may also be located on the primary side of the transformer.
CONNECT ALL WIRING BEFORE
POWERING TRANSFORMER
FOLLOW ALL APPLICABLE WIRING
AND SAFETY CODES.
HAZARDOUS VOLTAGES PRESENT
Drawing: 620B1346-8, Rev. -
TV0.3-28-56-ST Wiring
230 VAC INPUT
TV0.3-28-56-ST Wiring
115 VAC INPUT
Figure 2-4:
40 VDC Motor Power with a TV0.3-28-56-ST Transformer
www.aerotech.com
Chapter 2
29
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com