![Aerotech Ensemble CP Series Hardware Manual Download Page 70](http://html1.mh-extra.com/html/aerotech/ensemble-cp-series/ensemble-cp-series_hardware-manual_2863035070.webp)
Installation and Configuration
Ensemble CP
2.5.4. Opto-Isolated Inputs (J104)
The digital inputs are opto-isolated and may be connected to current sourcing or current sinking devices, as
shown in
Figure 2-38
and
Figure 2-39
. These inputs are designed to connect to other ground-referenced
circuits and are not intended for high-voltage isolation.
The opto-isolator's common connections can be directly connected to the drive's power supply; however,
doing so will effectively defeat the isolation and will reduce noise immunity.
Table 2-32:
Opto-Isolated Input Specifications
Input Voltage
Approximate Input Current
Turn On Time
Turn Off Time
+5 V
1 mA
200 usec
2000 usec
+24 V
6 mA
4 usec
1500 usec
Table 2-33:
Port 0 Digital Input Connector Pin Assignment (J104)
Pin#
Description
In/Out/Bi
17
Opto-Isolated Input 0 / CCW EOT Input
(1)
Input
18
Opto-Isolated Input 1 / CW EOT Input
(1)
Input
24
Input Common
-
25
Opto-Isolated Input 2 / Home Input
(1)
Input
26
Opto-Isolated Input 3
Input
(1) Software configured option
www.aerotech.com
Chapter 2
69
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com