Installation and Configuration
Ensemble CP
2.3.4. Encoder Fault Interface (J103)
The encoder fault input is for use with encoders that have a fault output. This is provided by some
manufactures and indicates a loss of encoder function. The active state of this input is parameter
configurable and the controller should be configured to disable the axis when the fault level is active.
Table 2-19:
Encoder Fault Interface Pin Assignment (J103)
Pin#
Description
In/Out/Bi
23
Encoder Fault Input
Input
1K
10K
.0
1
U
F
.0
0
1
+5V
ENCODER FAULT
J103-23
Figure 2-28:
Encoder Fault Interface Input (J103)