![Aerotech Ensemble CP Series Hardware Manual Download Page 34](http://html1.mh-extra.com/html/aerotech/ensemble-cp-series/ensemble-cp-series_hardware-manual_2863035034.webp)
Installation and Configuration
Ensemble CP
Drive
AC1
56V RED
Internal
Thermal
Switch
Primary Fuse
4A Slow-Blow
Primary Fuse
4A Slow-Blow
splice
splice
splice
splice
splice
splice
0V GRN
0V BLK
0V GRY
100V GRN
100V ORN
115V BRN
115V BLK
#18 WHT
#18 WHT
SAFETY
AC LO
115 VAC
50/60 HZ
INPUT
1. For 100 VAC primary input, parallel the 100 VAC taps and leave the 115 VAC taps unterminated.
2. For 200 VAC primary input, series the 100 VAC taps and leave the 115 VAC taps unterminated.
3. When using an isolation transformer, earth grounding of the AC2 input tap reduces electrical and audible noise emissions
and provides increased servo performance.
4. Additional or alternative fusing may be required for optimum protection
5. AC line filters are for CE compliance. Filters may also be located on the primary side of the transformer.
6. Transformer Primary Wiring: 0.8 mm
2
(#18 AWG) 300 V wire.
7. Transformer Secondary Wiring: 1.3 mm
2
(#16 AWG) 300 V wire.
Drawing: 620B1346-3
Secondary = 115 VAC (160 VDC Bus)
Secondary = 115 VAC (160 VDC Bus)
AC HI
0V BLU
56V YEL
56V RED
0V GRN
0V BLK
0V GRY
100V GRN
100V ORN
115V BRN
115V BLK
#18 WHT
#18 WHT
0V BLU
56V YEL
AC2
AC1
AC2
Mo
to
r
Su
p
p
ly
C
o
n
tro
l
Su
p
p
ly
5
4
4
6
6
7
7
5
1
1
3
Drive
AC1
Internal
Thermal
Switch
Frame Ground
SAFETY
AC LO
230 VAC
50/60 HZ
INPUT
TV0.3-28-56-ST Wiring
115 VAC INPUT
TV0.3-28-56-ST Wiring
230 VAC INPUT
AC HI
AC2
AC1
AC2
Mo
to
r
Su
p
p
ly
C
o
n
tr
o
l
Su
p
p
ly
5
5
2
2
3
Frame Ground
CONNECT ALL WIRING BEFORE
POWERING TRANSFORMER
FOLLOW ALL APPLICABLE WIRING
AND SAFETY CODES
HAZARDOUS VOLTAGES PRESENT
Figure 2-8:
160 Volt DC Bus from 115 and 230 VAC Source (TV0.3-56)
www.aerotech.com
Chapter 2
33