2.1. Input Power Connections
The XC2 has two DC input power connectors. One connector is for control power and the other
connector is for motor power. For a full list of electrical specifications, refer to
for a System Interconnection Drawing.
2.1.1. Control Supply Connector
The Control Supply input supplies power to the communications and logic circuitry of the XC2 . The
+24V
input is connected to an internal fuse. Refer to
for the internal fuse value and part
number. For an isolated DC supply, connect
0V
to protective ground at the supply. Use twisted pair
wiring to minimize radiated noise emissions (refer to
).
IMPORTANT
: Refer to local electrical safety requirements to correctly size external system
wires.
Figure 2-1:
Control Supply Connections
Table 2-1:
Control Supply Connector Wiring Specifications
Pin
Description
Recommended Wire Size
+24 V
24 VDC (±10%) Control Power Input
(2 A max, 0.4 A typical without brake)
0.34 mm
2
(#22 AWG)
0 V
Control Power Common Input
0.34 mm
2
(#22 AWG)
Protective Ground
0.34 mm
2
(#22 AWG)
Table 2-2:
Mating Connector Part Numbers for the Control Supply Connector
Type
Aerotech
P/N
Third Party
P/N
Screw
Torque: N·m
Wire Size:
mm
2
[AWG]
3-Pin Terminal Block
ECK02456
Phoenix 1839610
0.22 - 0.25
2.5 - 0.05 [14-30]
2.1. Input Power Connections
XC2 Hardware Manual
28
www.aerotech.com
Summary of Contents for Automation1 XC2
Page 1: ...Revision 2 01 Automation1 XC2 PWM Digital Drive HARDWARE MANUAL...
Page 12: ...This page intentionally left blank Agency Approvals XC2 Hardware Manual 12 www aerotech com...
Page 24: ...Figure 1 4 Dimensions EB1 1 2 2 Dimensions XC2 Hardware Manual 24 www aerotech com...
Page 96: ...Index XC2 Hardware Manual This page intentionally left blank 96 www aerotech com...