Npaq® Hardware Manual
Maintenance
Table 4-7:
Drive Interface Jumper Settings
Jumpers
Positions
Function
BW1
In
Bus #1 Uni-polar supply only
Out *
Bus #1 Uni-polar / Bipolar supply
BW2
In
Bus #2 Uni-polar supply only
Out *
Bus #2 Uni-polar / Bipolar supply
BW10, 11, 12
In *
Connects Bus Supply (B-, RTN, B+) between Axis 1 and 2
Out
Splits Bus Supply (B-, RTN, B+) between Axis 1 and 2
BW20, 21, 22
In *
Connects Bus Supply (B-, RTN, B+) between Axis 2 and 3
Out
Splits Bus Supply (B-, RTN, B+) between Axis 2 and 3
BW30, 31, 32
In *
Connects Bus Supply (B-, RTN, B+) between Axis 3 and 4
Out
Splits Bus Supply (B-, RTN, B+) between Axis 3 and 4
BW40, 41, 42
In *
Connects Bus Supply (B-, RTN, B+) between Axis 4 and 5
Out
Splits Bus Supply (B-, RTN, B+) between Axis 4 and 5
BW50, 51, 52
In *
Connects Bus Supply (B-, RTN, B+) between Axis 5 and 6
Out
Splits Bus Supply (B-, RTN, B+) between Axis 5 and 6
JP1
In *
Disable Axis power monitor for Brake
Out
Enable Axis power monitor for Brake (Additional wiring and hardware is
required)
* default
110
Chapter 4
www.aerotech.com