24/11/2022, 15:52
https://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA024&cert=ZC12-20120147
https://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA024&cert=ZC12-20120147
19/37
Used to enable/disable measurement reports for various sensors that is more than the upper limit value or less than the lower limit value.
Size: 1 Byte, Default Value: 0
Setting
Description
0
Disable
1
Temperature upper level
2
Humidity upper level
4
Lux upper level
8
UV upper level
16
Temperature lower level
32
Humidity lower level
64
Lux lower level
128
UV lower level
Parameter 49: Temperature Upper Limit
Set upper limit level for temperature set in scale of 0.1. Scale is determined by Param64. If (Current measurement) > (Upper Limit), then report sensor.
Size: 2 Byte, Default Value: 280
Setting
Description
-400 - 1000
Set upper limit level for temperature
Parameter 50: Temperature Lower Limit
Set lower limit level for temperature set in scale of 0.1. Scale is determined by Param64. If (Current Measurement) < (Lower limit), then report sensor.
Size: 2 Byte, Default Value: 0
Setting
Description
-400 - 1000
Set lower limit level for temperature
Parameter 51: Temperature Recover Limit