Parameter 61: Out-of-limit State
This is read only and bit mask. Out of the limit state of sensors.
Size: 1 Byte, Default Value: 0
Setting
Description
0
within limit
1
Temperature upper level
2
Humidity upper level
4
Lux upper level
8
UV upper level
16
Temperature lower level
32
Humidity lower level
64
Lux lower level
128
UV lower level
Parameter 64: Temperature Scale
Set the scale for temperature when reports.
Size: 1 Byte, Default Value: 0
Setting
Description
0
Celsius
1
Fahrenheit
Parameter 81: LED Activity
Allow user to enable/disable LED activity of specific reports sent by sensor. Button press indicator is not affected by this.
Size: 1 Byte, Default Value: 1