Parameter 43: Lux Threshold
Size: 2 Byte, Default Value: 250
Setting
Description
0 - 10000
Lux Threshold 0 = disabled
Parameter 44: UV Threshold
Size: 1 Byte, Default Value: 1
Setting
Description
0 - 11
UV Threshold 0 = disabled
Parameter 45: Threshold Check Time
Set threshold check time in seconds if the threshold is enabled via Parameter 40.
Size: 2 Byte, Default Value: 240
Setting
Description
1 - 65535
Set threshold check time in seconds when USB powered
60 - 65535
Set theshould check time in secons when Battery powered
Parameter 46: Low Temperature Report
Enable/Disable alarm report for low temperature
Size: 1 Byte, Default Value: 1
Setting
Description
0
Disable
1
Enable
Parameter 48: Sensor Limit Control