24/11/2022, 15:52
https://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA024&cert=ZC12-20120147
https://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA024&cert=ZC12-20120147
17/37
Setting
Description
0 - 11
Set threshold of UV.
Parameter 39: Low Battery Threshold
Configure low battery report threshold, sends low battery report via notification and battery report when battery level drops under setting. Unit %.
Size: 1 Byte, Default Value: 50
Setting
Description
10 - 90
Configure low battery report threshold
Parameter 40: Threshold Check Enable/Disable
Enable/Disable threshold reporting, check time can be adjusted by Param45.
Size: 1 Byte, Default Value: 0
Setting
Description
0
disable all threshold reports
1
enable all threshold reports
Parameter 41: Temperature Threshold
Threshold = (Value * 0.1) Scale is determined by Param64.
Size: 1 Byte, Default Value: 10
Setting
Description
0 - 255
Threshold = (Value * 0.1) Scale is determined by Param64. 0 = disable.
Parameter 42: Humidity Threshold
Humidity range = 1% to 50%,
Size: 1 Byte, Default Value: 5
Setting
Description
0 - 50
Humidity range = 1% to 50%, 0 = disable.