24/11/2022, 15:52
https://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA024&cert=ZC12-20120147
https://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA024&cert=ZC12-20120147
11/37
Group Number
Maximum
Nodes
Description
1
5
Lifeline
2
5
Basic Set Command will be sent to the associated device when motion trigger or untrigger. The
basic set value is determined by Param11, Param12. See Param13 for more information.
3
5
Basic Set: When the temperature change value is over or under the threshold set by Param16.
Scale is determined by Param64.
4
5
Basic Set: When the temperature change value is under or over the threshold set by Param17.
Scale is determined by Param64.
5
5
Basic Set: When the current humidity is over or under the threshold set by Param14
6
5
Basic Set: When the current humidity is under or over the threshold set by Param15
7
5
Basic Set: When the current light/lux is over or under the threshold set by Param18
8
5
Basic Set: When the current light/lux is under or over the threshold set by Param19.
9
5
Basic Set: When the current UV is over or under the threshold set by Param20
10
5
Basic Set: When the current UV is under or over the threshold set by Param21
11
5
Sensor Multilevel Report: When sensors above over limit or below under limit.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further
enhanced features.
IMPORTANT:
Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the
desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the
same logic applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 1: Beaming Enable/Disable
Used to enable/disable beaming.If set to 1, FLiRs commands will be supported. But the device must be re-included into the network to activate it.
Size: 1 Byte, Default Value: 1