24/11/2022, 15:52
https://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA024&cert=ZC12-20120147
https://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA024&cert=ZC12-20120147
14/37
Parameter 10: Power Status
This value is Readonly. Used to report the power status (USB or Battery powered) The device must be re-included in the network to change the role type.
Size: 1 Byte, Default Value: 0
Setting
Description
0
When battery powered, the device will act as RSS.
1
When USB cable insert, the device will act as LSS.
Parameter 11: Motion Group Control(Group2)
Set control of other devices on group2 based on motion trigger.
Size: 1 Byte, Default Value: 0
Setting
Description
0
Send BASIC_SET (0xFF) when motion is triggered to associated device Send BASIC_SET (0x00) when motion
is untriggered to associated device
1
Send BASIC_SET (0x00) when motion is triggered Send BASIC_SET (0xFF) when motion is untriggered
2
Send BASIC_SET (0xFF) when motion is triggered, Nothing when motion untriggered.
3
Send BASIC_SET (0x00) when motion is triggered, Nothing when motion untriggered.
4
Send BASIC_SET (0x00) when motion is untriggered, Nothing when motion triggered.
5
Send BASIC_SET (0xFF) when motion is untriggered, Nothing when motion triggered.
6
Send BASIC_SET (value is configured by parameter 12) when motion is triggered to associated devices. Send
BASIC_SET (value is configured by parameter 12) when motion is untriggered.
Parameter 12: Motion Group Value Setting
Set Basic Set value for Group2. The MSB will act as the basic set value when motion trigger. The LSB will act as the basic set value when motion untrigger. E.g.
value=0x0A00, then BASIC_SET(0x0A) will be sent when motion trigger, BASIC_SET(0x00) will be sent when motion untrigger.
Size: 2 Byte, Default Value: 65280
Setting
Description
0 - 65535
Set Basic Set value for Group2.