Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measured temperature(this value) send BASIC_SET
(0x00) to associated devices. E.g. Value 155 means 15.5 C. Value 600 means 60.0 F.
Size: 2 Byte, Default Value: 155
Setting
Description
-400 - 850
Set threshold of temperature
Parameter 18: Over Light Group Threshold (Group7)
Set threshold of Light/Lux. If measured light/lux >= (this value) send BASIC_SET (0xFF) to associated devices. If measured light/lux < (this value) send
BASIC_SET (0x00) to associated devices.
Size: 2 Byte, Default Value: 2000
Setting
Description
0 - 30000
Set threshold of Light/Lux.
Parameter 19: Under Light Group Threshold (Group8)
Set threshold of Light/Lux. If measured light/lux(this value) send BASIC_SET (0x00) to associated devices.
Size: 2 Byte, Default Value: 100
Setting
Description
0 - 30000
Set threshold of Light/Lux.
Parameter 20: Over UV Group Threshold (Group9)
Set threshold of UV. If measured UV >= (this value) send BASIC_SET (0xFF) to associated devices. If measured UV < (this value) send BASIC_SET (0x00) to
associated devices.
Size: 1 Byte, Default Value: 8
Setting
Description
0
Set threshold of UV.
Parameter 21: Under UV Group Threshold (Group10)
Set threshold of UV. If measured UV(this value) send BASIC_SET (0x00 to associated devices.)
Size: 1 Byte, Default Value: 1