24/11/2022, 15:52
https://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA024&cert=ZC12-20120147
https://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA024&cert=ZC12-20120147
12/37
Setting
Description
0
Disable
1
Enable
Parameter 2: Motion Retrigger Time
Presence re-detection time set in second to allow motion sensor to reset timeout of motion sensor. In this time, the motion sensor can not be triggered again. If this
value reach zero, the timeout configuration value set by Param3 will be reset. This setting value must always be less than timeout configuration.0 - disable1~3600
- timeout set in seconds
Size: 2 Byte, Default Value: 30
Setting
Description
30 - 3600
timeout set in seconds
Parameter 3: Motion Untrigger Time
Timeout configuration set in second for motion sensor to send no trigger status.
Size: 2 Byte, Default Value: 240
Setting
Description
30 - 3600
timeout set in seconds
Parameter 4: Motion Sensitivity
Set the sensitivity of motion sensor.
Size: 1 Byte, Default Value: 11
Setting
Description
0
Disable
1 - 11
sensitivity range
Parameter 5: Motion Report Type
Set which command class will be sent when the motion sensor is triggered or detriggered.
Size: 1 Byte, Default Value: 2