8
Sentinel
™
Data Loggers
Sentinel
™
Data Loggers
9
RECORDING
Storage Rate:
250ms to 12 hrs
Recording Session Length:
1 minute to 8 weeks selectable from table
or user programmable from computer
Total Memory:
Record 480,000 events (Size: 1MB)
Date and Time:
MM/DD/YY, DD/MM/YY, hh:mm:ss.sss
(24hr and AM/PM)
Storage Technique:
Start/Stop, FIFO, XRM™
(Extended Recording Mode)
INPUT
Three sets of recessed banana jacks for voltage inputs for differential
measurements. 64-samples/cycle are taken to calculate TRMS value for
each input.
INTERFACE
Output:
USB 2.0 Compliant
Isolation:
Optically isolated, 5.5kVrms maximum
Speed:
115.2 kbps
MECHANICAL
Dimensions:
6.73 x 4.76 x 2.17" (171 x 121 x 55mm)
Weight:
1.8 lbs (0.8kg) including the batteries
Case:
Polycarbonate UL94-V2
ENVIRONMENTAL
Operating Temperature:
14° to 122°F (-10° to 50°C)
Storage Temperature:
-4° to 140°F (-20° to 60°C)
Relative Humidity:
Up to 85% @ 95°F (35°C), Non-condensing
Altitude:
2000m
SAFETY
Safety:
600V Cat. III, 300V Cat. IV
Vibration:
IEC 68-2-6 (1.5mm 10Hz-55Hz)
Shock:
IEC 68-2-27 (30G)
Drop:
IEC 68-2-32 (1m)