14
Clamp-on Ground Resistance Tester Model 6417
2.8 Button Functions
Button
Description
▲
• When the rotary switch is set to
W
+A or A:
Increases the brightness
of the display, making it easier to read the display in an environment with
strong background illumination. Highlighting activated for 30 seconds.
• When the rotary switch is set to SET-UP or
MR:
Serves as the
▲
arrow when browsing in the menus and values. The brightness of the
display does not change when device is set to
SET-UP
or
MR
.
MEM
▼
• When the rotary switch is set to
W
+A
or
A:
Records the measured
value. All of the data is recorded in the Standard or Advanced mode.
• When the rotary switch is set to SET-UP
or
MR
: Serves as the
▼
arrow when browsing in the menus and values.
►
• When the rotary switch is set to
W
+A (Advanced Mode):
Short Press:
Switches the display through the following three modes:
-
Display of the impedance recalculated at the selected frequency.
-
Display of the contact voltage (product Z*I).
-
Display of R and L.
Long Press:
Enables or disables the audible alarms.
• When the rotary switch is set to SET-UP:
-
Validation when browsing in the menus and values.
• When the rotary switch is set to MR (Advanced Mode):
-
Switches the display through the measurement screens and the
measurement date/time.
HOLD
&
AUTO-HOLD
• When the rotary switch is set to
W
+A:
-
Freezes the displayed measurement for as long as the
HOLD
button
is pressed. The NOISE, clamp open (
), and alarm exceedence ( )
icons are visible, if they were active.
• When the rotary switch is set to MR or SET-UP:
-
Enables or disables the Bluetooth
®
connection.
• AUTO-HOLD Function:
If the
AUTO-HOLD
mode was enabled during instrument
SET-UP
(see
§ 4.4, menu #11), opening the clamp acts as the identical state to the
HOLD
mode for as long as the clamp is open. The benefit of this function
is that it makes it easy to freeze the measurement with one hand, when
access to the
HOLD
button is difficult.
If the
HOLD
button is not pressed during this time, closing the clamp
automatically exits the
AUTO-HOLD
mode.
www.
GlobalTestSupply
.com
Find Quality Products Online at: