EKI-7706 Series User Manual
9
2.3
Installing the Switch
You can mount the switch to a DIN rail or to a wall. The switch is equipped with a DIN
rail clip assembly and a wall mounting bracket for either configuration.
2.3.1
DIN Rail Mounting
The DIN rail mount option is the quickest installation option. Additionally, it optimizes
the use of rail space.
The metal DIN rail kit is secured to the rear of the switch. The device can be mounted
onto a standard 35mm (1.37”) x 75 mm (3”) height DIN rail. The devices can be
mounted vertically or horizontally. Refer to the following guidelines for further infor-
mation.
2.3.1.1
Installing the DIN-Rail Mounting Kit
1.
Position the rear panel of the switch directly in front of the DIN rail, making sure
that the top of the DIN rail clip hooks over the top of the DIN rail, as shown in the
following illustration.
Make sure the DIN rail is inserted behind the spring mechanism.
2.
Once the DIN rail is seated correctly in the DIN rail clip, press the front of the
switch to rotate the switch down and into the release tab on the DIN rail clip.
If seated correctly, the bottom of the DIN rail should be fully inserted in the
release tab.
Figure 2.1 Installing the DIN-Rail Mounting Kit
Note!
A corrosion-free mounting rail is advisable.
When installing, make sure to allow for enough space to properly install
the cabling.
Warning!
Do not install the DIN rail under or in front of the spring mechanism on
the DIN rail clip to prevent damage to the DIN rail clip or the DIN rail.
DIN rail clip
DIN rail
DIN rail clip
release tab
Summary of Contents for EKI-7706 Series
Page 1: ...User Manual EKI 7706 Series 4FE 2G SFP 4GE 2G SFP L2 Managed Switch...
Page 14: ...Chapter 1 1Product Overview...
Page 20: ...Chapter 2 2Switch Installation...
Page 37: ...Chapter 3 3Configuration Utility...
Page 43: ...Chapter 4 4Managing Switch...
Page 163: ...Chapter 5 5Troubleshooting...