EKI-7706 Series User Manual
121
4.9.6.3
RMON Alarm
The RMON Alarm page allows you to configure RMON statistics group and alarm
groups.
To access this page, click
Management
>
RMON
>
RMON Alarm
.
Figure 4.126 Management > RMON > Rmon Alarm
The following table describes the items in the previous figure.
The ensuing table for
Alarm Information
lists the following settings (informational
only):
Index, Interval, Variable, Sample Type, Rising Threshold, Falling Threshold,
Rising Event Index, Falling Event Index, Owner and
Delete
Item
Description
Index
Enter the index entry (1 to 65535) to define a specific Alarm Collection
history entry.
Interval
Enter a value (1 to 2147483647) to define the interval value for the
Alarm Collection history.
Variable
Enter the alarm variables to define the monitoring triggers.
Sample Type
Enter the variable sample type.
Rising Threshold
Enter the rising alarm threshold trigger.
Falling Threshold
Enter the falling alarm threshold trigger.
Rising Event Index
Enter the rising event index (1-65535) to define the alarm group.
Falling Event Index
Enter the falling event index (1-65535) to define the alarm group.
Owner
Enter the name of the owner of the RMON alarm group.
Apply
Click
Apply
to save the values and update the screen.
Summary of Contents for EKI-7706 Series
Page 1: ...User Manual EKI 7706 Series 4FE 2G SFP 4GE 2G SFP L2 Managed Switch...
Page 14: ...Chapter 1 1Product Overview...
Page 20: ...Chapter 2 2Switch Installation...
Page 37: ...Chapter 3 3Configuration Utility...
Page 43: ...Chapter 4 4Managing Switch...
Page 163: ...Chapter 5 5Troubleshooting...