Command Set
4-2 ADAM 4000 Series User’s Manual
4.1 Introduction
In order to avoid communication conflicts among devices trying to send
data simultaneously, all the traffics are coordinated by the host
computer. This action is initiated by the host computer using a
command/response protocol.
When the modules are not transmitting, they are in listening mode. The
host issues a command to a module with a specified address and waits
for the module’s response. If there is no response, a timeout aborts the
sequence and returns the control to the host.
Changing ADAM’s configuration might require the module to perform
auto calibration before changes may take effect. This is the case when
the range is modified especially. The module has to perform all stages
of auto calibration which is also performed during the start up. When
the calibration process is underway, the module does not respond to any
other commands. The command set in the following pages includes the
exact delays that might occur as modules are reconfigured.
4.2 Syntax
[delimiter character][address][command][data][checksum] [carriage
return]
Every command begins with a delimiter character. There are four valid
characters: a dollar sign $, a pound sign #, a percentage sign % and an
at sign @.
The delimiter character is followed by a two-character address
(hexadecimal) that specifies the target module. The actual
two-character command follows by the address. Depending on the
command, an optional data segment may follows by a command string.
Furthermore, an optional two-character checksum may be appended to
the total string. Every command is terminated by a carriage return (cr).
ALL COMMANDS SHOULD BE ISSUED IN UPPERCASE
CHARACTERS!
Summary of Contents for Data Acquisition Modules ADAM 4000
Page 1: ...ADAM 4000 Data Acquisition Modules User s Manual ...
Page 7: ...Introduction 1 ...
Page 11: ...Installation Guideline 2 ...
Page 28: ...I O Modules 3 ...
Page 98: ...Chapter 3 Chapter 3 I O Modules 3 71 Figure 3 69 ADAM 4069 Form A Relay Output ...
Page 104: ...Command Set 4 ...
Page 147: ...Analog Input Module Command Set 5 ...
Page 215: ...Analog Output Module Command Set 6 ...
Page 236: ...Digital I O Relay ouput and Counter Frequency Command Set 7 ...
Page 313: ...Calibration 8 ...
Page 329: ...Technical Specifications A ...
Page 335: ...Appendix A Appendix A Technical Specification A 7 Figure A 2 ADAM 4011D Function Diagram ...
Page 337: ...Appendix A Appendix A Technical Specification A 9 Figure A 3 ADAM 4012 Function Diagram ...
Page 339: ...Appendix A Appendix A Technical Specification A 11 Figure A 4 ADAM 4013 Function Diagram ...
Page 341: ...Appendix A Appendix A Technical Specification A 13 Figure A 5 ADAM 4016 Function Diagram ...
Page 343: ...Appendix A Appendix A Technical Specification A 15 Figure A 6 ADAM 4017 4017 Function Diagram ...
Page 349: ...Appendix A Appendix A Technical Specification A 21 Figure A 8 ADAM 4018M Function Diagram ...
Page 351: ...Appendix A Appendix A Technical Specification A 23 Figure A 9 ADAM 4019 Function Diagram ...
Page 355: ...Appendix A Appendix A Technical Specification A 27 Figure A 11 ADAM 4024 Function Diagram ...
Page 357: ...Appendix A Appendix A Technical Specification A 29 Figure A 12 ADAM 4050 Function Diagram ...
Page 377: ...Data Formats and I O Ranges B ...
Page 389: ...Technical Diagrams C ...
Page 392: ...Technical Diagrams C 4 ADAM 4000 Series User s Manual Figure C 3 DIN Rail Mounting ...
Page 394: ...Technical Diagrams C 6 ADAM 4000 Series User s Manual Figure C 5 Panel Mounting ...
Page 395: ...Appendix C Appendix C Technical Diagrams C 7 C 2 3 Piggyback Stack Figure C 6 Piggyback Stack ...
Page 396: ...Utility Software D ...
Page 404: ...RS 485 Network E ...
Page 411: ...How to use the Checksum feature F ...
Page 415: ...ADAM 4000 I O Modbus Mapping Table G ...
Page 428: ...Changing Configuration to Modbus Protocol H ...